<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Dr. SAGURA Medizintechnik</title>
	<atom:link href="http://blog.sagura.royalmedicalsystems.com/?feed=rss2" rel="self" type="application/rss+xml" />
	<link>http://blog.sagura.royalmedicalsystems.com</link>
	<description>Medical and research systems for EEG and PSG</description>
	<lastBuildDate>Sat, 09 Aug 2008 19:29:14 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>PureLight Sensor from Nonin</title>
		<link>http://blog.sagura.royalmedicalsystems.com/?p=8</link>
		<comments>http://blog.sagura.royalmedicalsystems.com/?p=8#comments</comments>
		<pubDate>Sat, 09 Aug 2008 19:24:44 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[PSG Sensors]]></category>
		<category><![CDATA[PureLight Sensor]]></category>

		<guid isPermaLink="false">http://blog.sagura.royalmedicalsystems.com/?p=8</guid>
		<description><![CDATA[PureLight Sensor Technology
PureLight® sensors produce a high-intensity pure light spectrum which eliminates variations in readings from patient-to-patient and sensor-to-sensor.
The PureLight Principle
Red and infrared light sources (LEDs) are essential to pulse oximetry sensors.

The red LED measures deoxygenated hemoglobin.
The infrared LED measures oxygenated hemoglobin

Common red LEDs may produce a secondary spectrum emission (contamination)

Contamination impacts the oxygenated hemoglobin [...]]]></description>
			<content:encoded><![CDATA[<h1>PureLight Sensor Technology</h1>
<p><img src="http://nonin.com/images/pureLight.gif" border="0" alt="" align="right" />PureLight® sensors produce a high-intensity pure light spectrum which eliminates variations in readings from patient-to-patient and sensor-to-sensor.</p>
<h2>The PureLight Principle</h2>
<p>Red and infrared light sources (LEDs) are essential to pulse oximetry sensors.</p>
<ul>
<li>The red LED measures deoxygenated hemoglobin.</li>
<li>The infrared LED measures oxygenated hemoglobin</li>
</ul>
<h2>Common red LEDs may produce a secondary spectrum emission (contamination)</h2>
<ul>
<li>Contamination impacts the oxygenated hemoglobin measurement.</li>
<li>LED contamination shifts the oximeter»s calibration curve resulting in inaccurate SpO<sub>2</sub> readings below 80%.</li>
</ul>
<h2>PureLight red LEDs only produce the pure light spectrum</h2>
<ul>
<li>PureLight LEDs do not cause a shift in the oximeter’s calibration curve at SpO<sub>2</sub> levels below 80%.</li>
<li>Nonin PureLight Sensors eliminate variations in readings from patient-to-patient and sensor-to-sensor.</li>
</ul>
<p><img src="http://nonin.com/images/sensor-calibration.jpg" border="0" alt="Graph: Oximeter Calibration Curve" /></p>
<p>Accurate and dependable SpO<sub>2</sub> readings start with PureLight sensors.</p>
]]></content:encoded>
			<wfw:commentRss>http://blog.sagura.royalmedicalsystems.com/?feed=rss2&amp;p=8</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Dr. SAGURA Medizintechnik</title>
		<link>http://blog.sagura.royalmedicalsystems.com/?p=5</link>
		<comments>http://blog.sagura.royalmedicalsystems.com/?p=5#comments</comments>
		<pubDate>Fri, 08 Aug 2008 15:38:02 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Medical and research systems for EEG and PSG]]></category>

		<guid isPermaLink="false">http://blog.sagura.royalmedicalsystems.com/?p=5</guid>
		<description><![CDATA[Over 25 years of providing Reliability &#8211; Quality Service to the Neurophysiological Community. High Quality Medical EEG/PSG Data Acquisition Amplifier Systems for Pediatrics and Adult incl. Isolated Medical Grade Power System and Data Transmission. Optical Isolation for highest Patient Safety are manufactured in Germany and CE marked according to 93/42/EWG European Community directive. Simultaneous recording [...]]]></description>
			<content:encoded><![CDATA[<div class="descr">Over 25 years of providing Reliability &#8211; Quality Service to the Neurophysiological Community. High Quality Medical EEG/PSG Data Acquisition Amplifier Systems for Pediatrics and Adult incl. Isolated Medical Grade Power System and Data Transmission. <strong>Optical Isolation</strong> for highest Patient Safety are manufactured in Germany and <a href="http://systems.sagura.com/tuvnord.jpg"><strong>CE marked according to 93/42/EWG</strong> European Community directive</a>. <strong>Simultaneous recording</strong> of high quality EEG traces and high resolution <strong>multicamera digital video</strong> offer enhanced diagnostic capabilities (e.g. in Epilepsy and PSG diagnostics).</div>
<p>See please <a class="wp-caption" title="Dr.SAGURA" href="http://home.sagura.com" target="_blank">sagura.com</a></p>
]]></content:encoded>
			<wfw:commentRss>http://blog.sagura.royalmedicalsystems.com/?feed=rss2&amp;p=5</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>